Repository logo
 

Data pre-processing for process optimization at a drinking water treatment plant in Ugu District Municipality, South Africa

dc.contributor.authorMagombo, James
dc.contributor.authorDzwairo, Bloodless
dc.contributor.authorMoyo, Sibusiso
dc.contributor.authorDewa, Mendon
dc.date.accessioned2017-03-14T06:24:02Z
dc.date.available2017-03-14T06:24:02Z
dc.date.issued2015
dc.description.abstractWhen testing and recording water quality data from treatment plants, errors arise. The errors are in the form of re-cordings left blank (missing values), obvious errors in writing or typing, or they can be as a result of values being very small to detect and are therefore censored. The censored values are known to be below the limit of detection (LOD). In statistical analysis, the blank cells can be filled with a certain value. Censored values are often corrected by substituting with a constant value throughout. This value will be a fraction of the limit of detection and most commonly used frac-tions are, half the limit of detection, the limit of detection divided by the square root of 2, or multiplying the limit of detection by 0.75. The direct substitution method for handling missing and values below the limit of detection results in a uniform distribution for values below the limit of detection, and a true distribution for those above. As a result, treat-ment of the values below the limit of detection is dependent upon their percentage in the sample size. An alternative method used will mimic the characteristic of the distribution pattern of the values above the limit of detection to esti-mate the values below it. This can be done with an extrapolation technique or maximum likelihood estimation. In this study, data from the Umzinto Water Treatment Plant was used to develop a data pre-processing program using Visual Basics for Applications (VBA) and Microsoft Excel 2013. The procedure involved 4 stages: data preparation, data pre-processing for blanks and non-detects, data pre-processing for the censored values and finally the identifica-tion of the outliers. The developed program was then used to pre-process raw water quality data, which resulted in satisfactory process time and data conversion. The methodology used can be borrowed for the pre-processing of data driven environmental models and hence it has a great influence on sustainability of water treatment plants.en_US
dc.dut-rims.pubnumDUT-004855en_US
dc.format.extent13 pen_US
dc.identifier.citationMagombo, J., Dzwairo, B., Moyo, S. & Dewa, M. 2015. Data pre-processing for process optimization at a drinking water treatment plant in Ugu District Municipality, South Africa. Environmental Economics. 6(1): 159-171.en_US
dc.identifier.issn1998-605X
dc.identifier.urihttp://hdl.handle.net/10321/2388
dc.language.isoenen_US
dc.publisherBusiness Perspectivesen_US
dc.relation.ispartofEnvironmental economics (Online)
dc.subjectOptimizationen_US
dc.subjectData pre-processingen_US
dc.subjectWater treatmenten_US
dc.subjectVisual basicsen_US
dc.subjectSustainabilityen_US
dc.titleData pre-processing for process optimization at a drinking water treatment plant in Ugu District Municipality, South Africaen_US
dc.typeArticleen_US
local.sdgSDG06

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
ee_2015_01__spec._issue_magombo.pdf
Size:
602.47 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.22 KB
Format:
Item-specific license agreed upon to submission
Description: