Repository logo
 

A secured access control architecture consideration for PLC based smart grids

dc.contributor.authorMooketsio, Thsepiso
dc.contributor.authorNleya, Bakhe
dc.contributor.authorDewa, Mendon
dc.contributor.authorMutsvangwa, Andrew
dc.date.accessioned2017-03-10T06:02:31Z
dc.date.available2017-03-10T06:02:31Z
dc.date.issued2015
dc.description.abstractAbstract—Power supply, distribution and generation industry is now turning the existing electrical grids to smart grids, thus making them more efficient in both effective power management and reliability, reduced production costs, and more environmen-tally friendly energy generation. Despite its attractive features, Smart Grid technology remains vulnerable to security threats. This paper summaries some of these potential security issues by exploring a data access control mechanism that ensures privacy to customers. The proposed access control mechanism gives selec-tive access to consumer data stored in data repositories and used by different smart grid users. A n attribute-based encryption (ABE) is suggested. The entire grid network is subdivided into clusters each with its own remote terminal unit (RTU) as well as a gateway smart meter. User data in a given cluster is aggregated and sent to the local substation where it is monitored by the RTU. RTUs and users have attributes and cryptographic keys dis-tributed by several key distribution centers (KDC). RTUs send data encrypted under a set of attributes. Users can decrypt infor-mation provided they have valid attributes. The access control scheme is quite resilient because of its b e i n g distributed in na-ture and does not rely on a single KDC to distribute keys. The encryption algorithm is based on Diffie-Hellman key establish-ment protocol and hash-based message authentication code, which allows smart meters at different clusters of the smart grid to mu-tually authenticate prior to data/information exchange and in the process maintaining low latency as well as relatively fewer au-thentication associated messages . Overall the control scheme is relatively collusion resistant.en_US
dc.format.extent5 pen_US
dc.identifier.citationMooketsio, T. et al. 2015. A secured access control architecture consideration for PLC based smart grids. Southern Africa Telecommunication Networks and Applications Conference (SATNAC) 2015. 413-417.en_US
dc.identifier.urihttp://hdl.handle.net/10321/2351
dc.language.isoenen_US
dc.publisherSATNACen_US
dc.publisher.urihttp://www.satnac.org.za/proceedings/2015/SATNAC%202015%20Proceedings.pdfen_US
dc.subjectAccess controlen_US
dc.subjectClustersen_US
dc.subjectDecentralizeden_US
dc.subjectAttribute-based encryptionen_US
dc.subjectHomomorphic Encryptionen_US
dc.subjectSmart metersen_US
dc.titleA secured access control architecture consideration for PLC based smart gridsen_US
dc.typePresentationen_US
local.sdgSDG07

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Mooketsio_SATNAC_2015_Proceedings.pdf
Size:
372.77 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.22 KB
Format:
Item-specific license agreed upon to submission
Description: